Elcon
Elcon UHF 1.8kW CANbus Charger
Choose options
Description:
Elcon 1.8kW Charger – Compact Power, Maximum Efficiency
Unlock reliable, high-efficiency EV charging with the Elcon 1.8kW Charger, a compact powerhouse engineered for performance, durability, and seamless integration. Whether you're upgrading your electric vehicle charging system or building a custom EV solution, the Elcon 1.8kW delivers dependable power with industry-leading precision.
🔌 Key Features:
-
High-Efficiency Output: 1.8kW of clean, regulated power optimized for lithium, lead-acid, and other common EV battery chemistries
-
Universal Input Range: Wide AC input voltage range (90–264V) supports global compatibility and versatility
-
Smart Charging Protocols: CAN bus communication for advanced BMS integration and intelligent charging control
-
Built for Longevity: Industrial-grade components and active cooling ensure long life and thermal stability, even in demanding environments
-
Plug-and-Play Integration: Compact form factor with pre-wired connectors for easy installation into custom or OEM EV platforms
Whether you're powering an electric motorcycle, go-kart, utility vehicle, or light-duty EV conversion, the Elcon 1.8kW Charger offers a perfect balance of size, power, and smart functionality.
🔋 Why Choose EV Source?
As a trusted leader in next-generation EV components, EV Source delivers premium charging solutions backed by expert support and fast, reliable service. We’re here to power your project — from concept to completion.
Product Models
| Hardware | Output Voltage Range | Max Output Current | Lithium Battery Charger Model | |
| 48V25A | 18-68 VDC | 25A | HK-H-H66-25 | |
| 72V25A | 25-99 VDC | 25A | HK-H-H99-25 | |
| 96V16A | 34-132 VDC | 16A | HK-H-H132-16 |
Features
1. Up to 95% efficiency
2. Strong protection
3. Extended temperature operating temperature range
4. 100% full load burn-in test
5. The high degree of protection up to IP67
6. Automotive-grade seismic rating
7. While charging the battery intelligent temperature compensation, maximizing battery life
8. The input voltage range AC85-AC280, for worldwide voltage range
Reliability
| Index | Data Definition |
Explanation |
| MTBF | 150,000 H | Reliability launched by the device failure rate |
Product Work Environment
| No. | Items | Technical Specifications |
| 1 | Operating Temperature | -40℃-+60℃ |
| 2 | Storage temperature | -40℃-+90℃ |
| 3 | Relative humidity | 5% -95% |
| 4 | Cooling | Air-cooled |
| 5 | Altitude | 3000m |
Electrical Characteristics
Input characteristics
Current and output voltage of each power input
| Input Voltage | Input Current IN |
Maximum Output Power |
| 110V | IN≤7A | 800W |
| 220V | IN≤9A | 1800W |
Output Characteristics
| Test | Ratings |
Tolerance Scope |
| Output Voltage Accuracy | 1% | / |
| Output Current Accuracy | 3% | / |
| The output voltage ripple factor | 1.5% | |
| Maximum DC output power | 1600W | / |
| Maximum Efficiency | ≥95% | / |
| Power Factor | 0.99 | / |
Protection Features
a) Output overvoltage protection;
b) Output overcurrent protection;
c) Output short circuit protection;
d) Input under voltage protection
e) Charger over-temperature protection;
f) Battery over-temperature protection。
Features
1. Up to 95% efficiency
2. Strong protection
3. Extended temperature operating temperature range
4. 100% full load burn-in test
5. The high degree of protection up to IP67
6. Automotive-grade seismic rating
7. While charging the battery intelligent temperature compensation, maximizing battery life
8. The input voltage range is AC85-AC280, for worldwide voltage range
Standby power charger standby power consumption of less than 5W
Starting current charger starting current is less than5A
Input Frequency (Frequency of input voltage fluctuation range)
|
Minimum |
Typical case |
Maximum |
|
40Hz |
50Hz/60Hz |
70Hz |
Safety features
Pressure resistance (Table 8 electrical test)
Ground Terminals (housing) Dielectric strength and are electrically connected to each other without a circuit between them. It should be able to withstand the test voltage in the table below 9,Test voltage(50~60)HzAC voltage between test terminals should not be corona, ionization, arcing or breakdown。
|
Input the housing |
1500V AC |
1min |
Leakage current ≤10mA |
|
Input to output |
1500V AC |
1min |
Leakage current ≤10mA |
|
Output of the housing |
500V AC |
1min |
Leakage current ≤10mA |
Insulation resistance
Charging machine charging circuit and ground insulation resistance (housing) between the ambient temperature (23±2) ℃And a relative humidity 80%~90%when, not less than 20MΩ。
Contact current
When a human or animal contacts with one or more devices or device accessible parts, the current flowing through their bodies should be less than GB/T13870.1-2008 The contact current perception threshold requirement, the current value of the charger contact Table 9。
|
Contact current category |
Alternating current mA |
DC current mA |
|
Limit |
≤0.75 |
≤2 |
Grounding resistance of less than 0.1Ω. Required grounding conductor yellow / green and white color line
Audio Noise (Table 10 Noise)
|
Noise |
Noise |
|
≤65dB |
distance 1.5m,A weight |
EMC characteristics
Electromagnetic compatibility charger to meet the GB / T 18487.3-2001 electromagnetic environment in 11.3 test requirements。
Lightning Level
|
Lightning indicators |
standard test |
|
TBD |
/ |