Elcon UHF 3.3kW CANbus Charger

  • Sale
  • $894.00
  • Regular price $1,100.00


HK-J-H66-40 Manual
HK-J-H99-40 Manual
HK-J-H132-32 Manual
HK-J-H198-23 Manual
HK-J-H440-10 Manual
HK-J-H650-6 Manual

Description


3.3KW UHF chargers are available in the following models.  The first number is the maximum voltage and the second number is the maximum current.

HK-J-H66-40 provides 18-66VDC output

HK-J-H99-40 provides 25-99VDC output

HK-J-H132-32 provides 34-132VDC output

HK-J-H198-23 provides 50-198VDC output

HK-J-H440-10 provides 110-440VDC output

HK-J-H650-6 provides 170-650VDC output

The HK-J series 3.3KW charger is designed for electric vehicle battery and battery management system interface. The product not only has high efficiency, small size, high stability, long life and other advantages, but also has a high degree of protection, highly reliable, full-featured protection and other features. The ideal power source for charging electric vehicles. Built-in thermal sensing device gives thermal overload protection that is automatically reset when cooled. Fully sealed encapsulation process, up to IP67 protection class, you can employ in any difficult environment without causing failure.

Main features 
Full casting process, air-cooled or water-cooled, can work reliably under conditions -40- + 60 degrees.

Weight 
8.9 lbs (3.9kg) without heatsink or fan.

Specifications  

Models

HK-J-H 99-40, 132-32, 198-23, 440-10

I

N

P

U

T

Input Voltage         

AC 85~265V

Frequency

45-65Hz

Input Current

16A

Power Factor

≥0.99 at over half power

Efficiency

≥94%  at full power

Idle Power

≤5W

O

U

T

P

U

T

Output

CV / CC

Output Ranges

25-99V, 33-132V, 50-198V, 110-440V

Output current Limits

Maximum 40A, 32A, 23A, 10A

Output Power

3300W @220vac or 1600W@110VAC

Voltage Accuracy

±1%

Current Accuracy

±2%

Ripple voltage

5%

 

A

U

X.

 

O

U

T

P

U

T

 

12V Power Supply

Output Voltage

12.5V

Current Rating

5A

Current Accuracy

±2%

Max. Current

5.5A±0.5A

Output  Power

≥62.5W

Ripple Voltage

1%

 

P

R

O

T

E

C

T

I

O

N

 

Input Overvoltage

AC270±5V

Input Under-voltage

AC80±5V

Output Overvoltage

1% over max voltage limit stops output

Output Under-voltage

5% below minimum voltage stops output

Output Overcurrent

1% over max. output current stops output

Over Temp. Protection

85deg C starts reduced power, over 90deg stops output

Short Circuit  Protection

Output stops

Reverse battery protection

Blown Fuse

Ground Protection

≤0.1milliohms

CAN Com. Protection

Communication failure stops output

 

C

O

M

CAN Communications

CAN IDs E5, E7, E8 and E9

Baud Rate  options

500Kbps

Terminating resistor

Not included

 

S

A

F

E

T

Y

Galvanic Isolation

Input to output: 2000VAC≤10mA input to ground: 2000VAC≤10mA
Output to ground: 2000VAC≤10mA, are 1min

Insulation Rating

Input to output, the signal end of the housing ≥10M Europe, the test voltage 1000VDC

Electromagnetic Immunity

Meet GB / T 18487.3-2001 11.3.1 Article

Electromagnetic noise

Meet GB / T 18487.3-2001 11.3.2 Article

Harmonic Current

Meet GB 17625.1-2003 6.7.1.1 Article

Inrush Current

≤6A

Current Rise Time

≤5S, overshoot ≤5%

Stop  response time

100% to 10% ≤50mS, 100% to 0% ≤200mS

Protection Class

IP67

Vibration Resistance

10-25Hz amplitude of 1.2mm, 25-500Hz 30m / s2, 8 hours a direction

Noise

≤60dB

MTBF

150000H

Working Environment

Relative humidity 5% -95% non-condensing

Operating Temperature

-40 ~ 60℃

Storage temperature

-55℃~ +85℃

Over-temperature protection

Stops when over 90deg C, resumes operating when cooled.